First Choice - PSMEL2000 - Two Door Power Supply / Exit Devices - 12/24V - 1 AMP
First Choice - PSMEL2000 - Two Door Power Supply / Exit Devices - 12/24V - 1 AMP
First Choice
Regular price
$544.50 USD
Regular price
$762.30 USD
Sale price
$544.50 USD
Unit price
per
SLK-FCH-PSMEL2000
Smart Self-Diagnosing Power Supply PSMEL200 Operates a pair of doors with two low current exit devices simultaneously or independently control two single door leaf's.
- Shall operate up to two (2) 24VDC panic hardware devices simultaneously
- Each lock output shall have an adjustable relock delay timer
- It shall control a pair of doors simultaneously or independently two doors
- Relay for each output to trigger external relays, ADA push plate switches, etc.
- Delayed follower relays shall control automatic door operators for doors that are always locked or for doors that are unlocked during the business day
- Two un-switched auxiliary voltage outputs shall provide/remove power to the lock outputs when activated
- A programmable FACP interface shall provide power/remove power to the lock outputs when activated
- Shall have LED status indicators monitor AC, FACP status & for lock output wiring supervision
- Intelligent logic shall provide protection against accidental shorting of lock outputs
Specifications
Smart Visual Indicators | • Output 1 & 2 = Red (ON) input LEDs indicate panic device status is energized (rapid blink/short or over current) (slow blink/open circuit) • FAI = Green (ON) FACP Input Triggered (Alarm Condition) • Battery Trouble = Red (ON) Battery Normal (slow blink/bad battery or no battery) • AC Trouble = Green (ON) AC normal (slow blink/AC low or missing) |
Visual Indicators |
• Output 1 (On/Over/Open) • Output 2 (On/Over/Open) • FAI (On/Off) • Battery (On/Off) • AC Trouble (On/Low or Missing) • AC Power (On/Off) |
Battery Backup | • Built-in charger for sealed lead acid or gel type batteries • Automatic switch over to stand-by battery when AC fails • Maximum charge current .65 amps • 4AA batteries will make emergency stand-by at least 30 minutes |
Input |
• Input 115VAC 60Hz, 2.5 amp or 230VAC, 50Hz, 1.5 amps • Two (2) N.O. Trigger Inputs |
Outputs | • Two (2) 24 VDC individually controlled lock outputs rated @ 1 amp each. Load connected not to exceed 1 amp. • One (1) 24VDC @ .08 amps filtered regulated auxiliary output. (Not affected by FACP trigger) • One (1)12 VDC @ .05 amp filtered regulated auxiliary output. (Not affected by FACP trigger) Note: Total combined current for the 24VDC outputs may not exceed 1.75 amp. • Two (2) follower N.O. outputs for controlling ADA actuators/ accessories • Two (2) momentary operator activation outputs • Trouble output relay for indicating low/AC Voltage and battery trouble. |
Dimensions | 13" x 12.5" x 3.5" (H x W x D) |
Code / Agency Listings | • UL File for Access Control Systems Units (UL 294) • CUL Listed – CSA Standard C22.2 No. 205-M983, Signal Equipment's • CSFM – California State Fire Marshal Approved |